Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Clin Oral Investig ; 28(4): 223, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507031

RESUMO

OBJECTIVES: An evaluation of the effectiveness of a new computational system proposed for automatic classification, developed based on a Siamese network combined with Convolutional Neural Networks (CNNs), is presented. It aims to identify endodontic technical errors using Cone Beam Computed Tomography (CBCT). The study also aims to compare the performance of the automatic classification system with that of dentists. METHODS: One thousand endodontically treated maxillary molars sagittal and coronal reconstructions were evaluated for the quality of the endodontic treatment and the presence of periapical hypodensities by three board-certified dentists and by an oral and maxillofacial radiologist. The proposed classification system was based on a Siamese network combined with EfficientNet B1 or EfficientNet B7 networks. Accuracy, sensivity, precision, specificity, and F1-score values were calculated for automated artificial systems and dentists. Chi-square tests were performed. RESULTS: The performances were obtained for EfficienteNet B1, EfficientNet B7 and dentists. Regarding accuracy, sensivity and specificity, the best results were obtained with EfficientNet B1. Concerning precision and F1-score, the best results were obtained with EfficientNet B7. The presence of periapical hypodensity lesions was associated with endodontic technical errors. In contrast, the absence of endodontic technical errors was associated with the absence of hypodensity. CONCLUSIONS: Quality evaluation of the endodontic treatment performed by dentists and by Siamese Network combined with EfficientNet B7 or EfficientNet B1 networks was comparable with a slight superiority for the Siamese Network. CLINICAL RELEVANCE: CNNs have the potential to be used as a support and standardization tool in assessing endodontic treatment quality in clinical practice.


Assuntos
Tratamento do Canal Radicular , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Assistência Odontológica , Dente Molar
2.
Dentomaxillofac Radiol ; 52(4): 20220363, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36988148

RESUMO

OBJECTIVES: This study aimed to assess and compare age estimation on panoramic radiography using the Kvaal method and machine learning (ML). METHODS AND MATERIALS: 554 panoramic radiographs were selected from a Brazilian practice. To estimate age using the Kvaal method, the following measurements were performed on the upper left central incisors and canines: tooth, pulp and root length; root and pulp width at three different levels: at the enamel-cementum junction (ECJ); midpoint between the enamel-cementum junction and; at the mid root level. For ML age estimation, radiomic, semantic and the radiomic-semantic attribute extractions were assessed. Nineteen semantic and 14 radiomic attributes and a single set of 33 semantic-radiomic attributes were extracted. Logistic Regression, Linear Regression, KNN, SVR, Decision Tree Reg, Random Forest Reg, Gradient Boost Reg e XG Boosting Reg were used for ML classification. For the Kvaal method, Mann-Whitney test, Spearman correlation coefficient, Student's t-test and linear regression with its respective coefficient of determination were used to estimate age and to assess data variability. RESULTS: Mean absolute error (MAE) and standard error estimate (SEE) were assessed. For the Kvaal method, upper incisors presented higher precision than canines (R²: 0.335, SSE: 7.108). Males presented better MAE and SEE values (5.29,6.96) than females (5.69,7.37). The radiomic-semantic attributes presented superior precision (MAE: 4.77) than the radiomic and semantic (MAE: 5.23) attributes. The XG Boosting Reg classifier performed better than the other six assessed classifiers (MAE: 4.65). ML (MAE: 4.77 presented higher age estimation precision than the Kvaal method (MAE: 5.68). CONCLUSION: The use of ML on panoramic radiographs can improve age estimation.


Assuntos
Determinação da Idade pelos Dentes , Inteligência Artificial , Masculino , Feminino , Animais , Radiografia Panorâmica , Determinação da Idade pelos Dentes/métodos , Polpa Dentária , Incisivo
3.
BMC Med Imaging ; 22(1): 4, 2022 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-34983424

RESUMO

BACKGROUND: This study aimed to investigate the effect of automatic exposure compensation (AEC) of intraoral radiographic systems on the gray values of dental tissues in images acquired with or without high-density material in the exposed region using different exposure times and kilovoltages. The influence of the distance of the high-density material was also investigated. METHODS: Radiographs from the molar region of two mandibles were obtained using the RVG 6100 and the Express systems, operating at 60 and 70 kV and 0.06, 0.10, and 0.16 s. Subsequently, a titanium implant was inserted in the premolar's socket and other images were acquired. Using the ImageJ software, two regions of interest were determined on the enamel, coronary dentine, root dentine, and pulp of the first and second molars to obtain their gray values. RESULTS: In the RVG 6100, the implant did not affect the gray values (p > 0.05); the increase in kV decreased it in all tissues (p < 0.05), and the exposure time affected only the root dentine and pulp. In the Express, only enamel and coronary dentine values changed (p < 0.05), decreasing with the implant presence and/or with the increase in exposure factors. The distance of the implant did not affect the results (p > 0.05). CONCLUSIONS: AEC's performance varies between the radiographic systems. Its effect on the gray values depends not only on the presence or absence of high-density material but also on the kV and exposure time used.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Radiografia Dentária Digital/métodos , Esmalte Dentário/diagnóstico por imagem , Polpa Dentária/diagnóstico por imagem , Dentina/diagnóstico por imagem , Humanos , Mandíbula/diagnóstico por imagem
4.
ScientificWorldJournal ; 2022: 4766305, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35087327

RESUMO

The aim of this study was to evaluate the root canal morphology of permanent maxillary molars by cone-beam computed tomography (CBCT) using the classifications of Weine et al. and Vertucci and to correlate the findings with sex, age, position in the dental arch, and prevalence of a second canal in the mesiobuccal root (MB2). A total of 414 scans were evaluated, corresponding to 1,000 teeth. The assessment consisted of coronal, axial, and sagittal reconstructions using i-CAT Workstation®. Type 0 was assigned when neither classification could be applied. The data were entered into an Excel spreadsheet and analyzed using SPSS. The chi-squared test or Fisher's exact test was used to compare the distribution of root canal morphology classified using the two systems. Analysis of the distribution of Weine types showed a predominance of type III in mesiobuccal roots, while type 0 predominated in distobuccal and palatal roots. Vertucci type IV predominated in mesiobuccal and distobuccal roots and type VII in palatal roots. There was no difference in the distribution of morphological canal types in permanent maxillary molars evaluated by CBCT according to sex, age group, or position in the dental arch of the patients. MB2 canals were identified in 68.4% of the teeth evaluated.


Assuntos
Variação Anatômica , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Cavidade Pulpar/diagnóstico por imagem , Maxila/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Adolescente , Adulto , Idoso , Criança , Cavidade Pulpar/anatomia & histologia , Feminino , Humanos , Masculino , Maxila/anatomia & histologia , Pessoa de Meia-Idade , Dente Molar/anatomia & histologia
5.
Oral Radiol ; 38(3): 356-362, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34529235

RESUMO

OBJECTIVES: To investigate the performance of radiographic systems with automatic exposure compensation (AEC) on the caries diagnosis in images acquired with different exposure parameters and in the presence of high-density material. Also, the image quality was assessed. METHODS: Forty posterior teeth (80 proximal surfaces) were radiographed using a phosphor plate and a CMOS system. Images were acquired with different exposure times (0.06, 0.10 and 0.16 s) and kilovoltages (60 and 70kVp), in the absence and presence of high-density material in the X-rayed region (control and high-density groups). Five radiologists assessed the caries using a 5-point scale. Diagnostic values were compared using two-way ANOVA. RESULTS: For both radiographic systems, there were no significant differences in the area under the ROC curve (0.60-0.73), sensitivity (0.79-0.87) and specificity (0.29-0.48) between the control and high-density groups, exposure times or kilovoltages (p > 0.05). For image quality, scores assigned to the control and high-density groups were similar in each exposure protocol in both systems. CONCLUSIONS: The presence of high-density material, exposure time and kilovoltage did not affect the caries diagnosis in any of the systems tested. It is recommended to use protocols with lower doses to reduce the patient's exposure.


Assuntos
Suscetibilidade à Cárie Dentária , Radiografia Dentária Digital , Humanos , Variações Dependentes do Observador , Curva ROC , Radiografia , Radiografia Dentária Digital/métodos
6.
J Periodontal Implant Sci ; 51(4): 264-275, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34387046

RESUMO

PURPOSE: Periodontitis is considered a local risk factor for medication-related osteonecrosis of the jaws (MRONJ). However, little is known about the progression of periodontitis in the presence of zoledronic acid (ZOL). The aim of this study was to evaluate the effects of the systemic use of ZOL on the progression of experimental periodontitis (EP) in rats, as ZOL could modulate the progression of periodontitis and concomitantly cause MRONJ in individuals with periodontitis. METHODS: Forty-eight male Wistar rats were randomly distributed in 6 groups (n=8 each). To induce EP, ligatures were placed around the right first mandibular molars. Three groups were treated with ZOL (0.15 mg/kg/week, intraperitoneal), and 3 with 0.9% saline solution (controls). In the ZOL/Lig30 and ZOL/Lig 15 groups, after 4 weeks of treatment with ZOL, EP was induced and euthanasia was performed after 30 and 15 days of EP induction, respectively. In both groups, the animals continued to receive ZOL after EP until the end of the experiment. In the Lig/ZOL group, EP was induced first, and 15 days later, ZOL was administered for 8 weeks, with euthanasia 1 week after the last dose. After euthanasia, the mandibles were evaluated using micro-computed microtomography (micro-CT) and histomorphometry. Bone loss was measured, and the presence of osteonecrosis was evaluated histologically. The data were evaluated using the Student t-test and the Mann-Whitney test, with a significance level of 5%. RESULTS: In the Lig/ZOL group, micro-CT revealed less alveolar bone resorption in the distal root (P<0.01) than in the control group (Lig/Con). Histomorphometric analysis confirmed less alveolar bone resorption in the Lig/ZOL group (P=0.001). Histologically, osteonecrosis was more common in the ZOL groups. CONCLUSION: ZOL decreased alveolar bone resorption in rats with EP. However, it presented a higher risk for MRONJ.

8.
Med. oral patol. oral cir. bucal (Internet) ; 25(3): e346-e352, mayo 2020.
Artigo em Inglês | IBECS | ID: ibc-196320

RESUMO

BACKGROUND: To evaluate the quality of oral cancer information in Brazilian Portuguese on Google, YouTube, and Instagram. MATERIAL AND METHODS: The first 100 links of each platform characterized the initial sample. The websites and Instagram were evaluated using the JAMA benchmarks, the Discern instrument, and the Flesch readability index (Flesch Reading Ease). The existence of Health on the Net (HON) code was also registered on websites. The usefulness of each video on YouTube was classified as not useful, slightly useful, moderately useful, or very useful. RESULTS: Thirty-four websites, 39 Instagram posts, and 57 videos were evaluated, of which 18 (33.3%) websites and 19 (48.7%) Instagram posts covered only 2 of the 4 JAMA benchmarks. For the Discern instrument, 20 (37%) and 18 (33.3%) websites exhibited low and moderate reliability, respectively, while 26 (66.7%) Instagram posts were of low confidence. The level of intelligibility of both websites and Instagram was difficult. Only three websites exhibited the HONcode. Forty-one (71.9%) videos on YouTube were moderately useful. CONCLUSIONS: Information on oral cancer on the Internet in Brazilian Portuguese is of low quality. Thus, educational and governmental institutions have a responsibility to produce and indicate reliable sources of information for the population


No disponible


Assuntos
Humanos , Neoplasias Bucais , Disseminação de Informação , Acesso à Internet , Informação de Saúde ao Consumidor/normas , Gravação em Vídeo , Redes Sociais Online , Brasil
9.
Imaging Sci Dent ; 50(4): 281-290, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33409136

RESUMO

PURPOSE: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). MATERIALS AND METHODS: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). RESULTS: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). CONCLUSION: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.

10.
Indian J Dent Res ; 30(3): 408-413, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31397417

RESUMO

AIM: The aim of this study is to evaluate the effect of different doses of the ionizing radiation (0 Gy, 10 Gy, 30 Gy, and 60 Gy) on the physical properties of dental materials. METHODOLOGY: Disc-shaped samples from each material (Ketac Molar Easymix, Vitro Molar, Vitremer, Vitro Fil Lc, Filtek Z 250 and Filtek Z 350) were made for water solubility, sorption analysis (n = 20), microhardness (n = 20), and surface roughness analysis (n = 24). Specimens were divided into four groups, according to radiation dose: control group (0 Gy), 10 Gy, 30 Gy, and 60 Gy. For water solubility and sorption analysis, the specimens were irradiated and were stored for 21 days to calculate the water solubility and sorption values. Microhardness analysis was carried out before and after irradiation doses. For surface roughness analysis, the specimens were submitted to brushing test, and after 24 h, initial surface roughness analysis was made in a rugosimeter. Subsequently, the samples were irradiated and final surface roughness analysis was made. The original water solubility and sorption, surface roughness, and microhardness values were subjected to ANOVA two-way statistical analysis and Paired t-test and Tukey post hoc test (α = 0.05), respectively. RESULTS: Water solubility and sorption values, and surface roughness values presented statistical difference between groups (0, 10, 30 e 60 Gy) for all materials. CONCLUSIONS: High doses of ionizing radiation (30 Gy and 60 Gy) increased the surface roughness, sorption, and solubility for the most materials.


Assuntos
Resinas Compostas , Materiais Dentários , Teste de Materiais , Radiação Ionizante , Solubilidade , Propriedades de Superfície
11.
Gen Dent ; 67(5): 72-76, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31454328

RESUMO

The objective of this study was to evaluate the influence of the radiopacity of composite resin restorations on the interpretation of phantom radiographic images and to correlate the diagnosis with clinical management. Eighty healthy extracted human third molars were divided into 4 groups (n = 20 each): 3 restorative groups and 1 group of untreated teeth. The radiopacity of the materials was evaluated objectively using 10-mm discs of the composite resins SureFil SDR Flow (SDR), Filtek Bulk Fill Flowable Restorative (Filtek Bulk), and Filtek Z250 XT (Z250). Standard Class II cavities were prepared in the teeth. In the SDR and Filtek Bulk groups, the respective material was placed as a 2-mm base, and the remainder of the cavity was restored with Z250. In the Z250 group, the entire preparation was filled with Z250 composite resin. Ten phantoms of 6 teeth each were created; each phantom included 1 molar selected randomly from each of the 4 groups and 2 healthy premolars. Bitewing radiographs of the phantoms were obtained with a digital phosphor plate system and stored. For the subjective analysis, 5 examiners evaluated each of the molars on the radiographs and established the diagnosis and treatment plan. The radiopacity of the materials was statistically similar (P = 0.413), and there was no statistically significant difference between groups in the interpretation of the images. The radiopacity of the materials met ISO standard 4049/2009. Diagnosis and decision-making were influenced by the radiopacity of the materials. Filtek Z250, which had the lowest radiopacity, was diagnosed correctly more often than SDR, which had higher radiopacity. Filtek Bulk had the highest opacity and the highest percentage of correct diagnoses. In clinical practice, radiographic visualization of restorations and dental structures is essential for establishing a correct diagnosis and treatment plan. A restorative material may be within the established requirements for radiopacity, but on radiographic evaluation it might not be differentiated from mineralized dental tissues.


Assuntos
Resinas Compostas , Cárie Dentária , Restauração Dentária Permanente , Radiografia Dentária Digital , Resinas Compostas/química , Materiais Dentários/química , Humanos , Teste de Materiais
12.
Pesqui. bras. odontopediatria clín. integr ; 19(1): 4073, 01 Fevereiro 2019. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-997964

RESUMO

Objective: To evaluate the impact of radiotherapy on enamel around restorations of glass ionomer cement (GIC) and fluoride tooth paste (FTP). Material and Methods: Eighty enamel blocks were made and randomly distributed into two groups, according to the fluoride therapy, non-fluoride tooth paste (NFTP) and FTP (n=40) and in subgroups in conformity with radiation dose (0, 10, 30 and 60 Gy). Roughness and microhardness enamel analyses were conducted before radiotherapy. Enamel cavities were made and restored with two GIC (Ketac Molar Easy Mix or Vitremer). Enamel blocks were submitted to 10, 30 and 60 Gy. Then, artificial enamel caries lesions were created by a pH-cycling procedure and FTP or NFTP were used as treatment. The restored enamel blocks were submitted to final roughness and microhardness analyses. Roughness increase (ΔR) and hardness loss (ΔH) values of enamel were submitted to ANOVA and Tukey test (p=0.05). Results: The irradiated enamel group showed statistically higher ΔR (0.44 ±0.2) and ΔH (99.26±7.0) values compared to non-irradiated group (ΔR = 0.051±0.02; ΔH=66.16±12.7) when a resin-modified GIC and NFTP were used. Conclusion: Higher radiation dose increased dissolution of bovine enamel. The use of GIC associated with FTP decreased roughness and increased enamel hardness after radiotherapy.


Assuntos
Radioterapia/métodos , Remineralização Dentária/efeitos adversos , Técnicas In Vitro/métodos , Esmalte Dentário , Cimentos de Ionômeros de Vidro/efeitos da radiação , Brasil , Análise de Variância , Testes de Dureza/métodos
13.
Braz. j. oral sci ; 18: e191638, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1095366

RESUMO

Aim: The aim of this study is to evaluate the effect of radiotherapy on the bond strength of resin-based composite restorations to dentin, performed either 24 h or 1 year before or after radiation. Methods: Ninety-six posterior teeth were randomly distributed into the following groups: IB (n = 16), irradiated teeth were restored 1 year after x-ray application; NB (n = 16), not irradiated teeth were stored for 1 year and then restored. IA (n = 32), teeth were restored and irradiated at 24 h or 1 year after the restoration. NA (n = 32), teeth were restored, not irradiated, and tested as IA. Eight samples from each group were randomly assigned to either the three-step or two-step etch-and rinse adhesive system procedure. The irradiated specimens were subjected to 60 Gy of x-ray radiation fractionally. The restored teeth were vertically sectioned, and 1-mm2 resin­dentin sticks were obtained and submitted to the microtensile bond strength test. The bond strength data were analyzed by two-way analysis of variance (ANOVA) followed by Tukey's test (p < 0.05). Failure modes were examined by optical microscopy and scanning electron microscopy. Results: The IB group showed lower bond strength values compared to the NB group. The bond strength values between the adhesive systems were not statistically different. Conclusion: The application of radiation dose decreased the bond strength of the adhesive restorations to dentin when the bonding procedure was conducted 1 year after in vitro radiotherapy


Assuntos
Radioterapia , Resistência à Tração , Dentina , Neoplasias de Cabeça e Pescoço
14.
Braz. dent. j ; 29(1): 99-104, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888715

RESUMO

Abstract Imaging exams have important role in diagnosis of cemento-osseous dysplasia (COD). Cone beam computed tomography (CBCT) stands out for allowing three-dimensional image evaluation. This study aimed to assess the prevalence of cases diagnosed as COD on CBCT scans, as well identify the main imaging features related to these lesions. An analysis was performed in a database containing 22,400 radiological reports, in which all cases showing some type of COD were initially selected. These CBCT exams were reevaluated to confirm the radiographic diagnosis and determine the prevalence and distribution of the types of COD with regard to gender, age and preferred location, while describing its most common imaging aspects. Data were presented using descriptive analyses. There were 82 cases diagnosed as COD in the CBCT images (prevalence of 0.4%). The distribution of patients was 11 (13.4%) male and 71 (86.6%) female, with a mean age of 49.8 years (age-range 17-85 years). There were 47 (57.3%) cases of periapical COD, 23 (28%) of focal COD and 12 (14.6%) of florid COD. The mandible was more affected than the maxilla. In most cases, the lesions were mixed or hyperdense. All COD had well-defined limits and there were no cases of tooth displacement. In conclusion, periapical COD was the most common type and the most affected bone was the mandible. Imaging evaluation is critical for diagnosis and dentists should bear in mind all possible radiographic presentations of COD in order to prevent misleading diagnoses and consequently, inadequate treatments.


Resumo Os exames por imagem têm papel importante no diagnóstico da displasia cemento-óssea (DCO). A tomografia computadorizada por feixe cônico (TCFC) se destaca por permitir a avaliação tridimensional da imagem. O objetivo neste estudo foi avaliar a prevalência de casos diagnosticados como DCO nos exames de TCFC, bem como identificar as principais características de imagem relacionadas a essas lesões. Uma análise foi realizada em um banco de dados contendo 22.400 laudos radiológicos, no qual todos os casos que apresentavam algum tipo de DCO foram inicialmente selecionados. Estes exames foram reavaliados para confirmar o diagnóstico radiográfico e determinar a prevalência e distribuição dos tipos de DCO em relação ao sexo, idade e localização preferencial, além de descrever seus aspectos imaginológicos mais comuns. Os dados foram apresentados por meio de análise descritiva. Oitenta e dois casos foram diagnosticados como DCO nas imagens de TCFC (prevalência de 0,4%). A distribuição dos pacientes foi de 11 (13,4%) homens e 71 (86,6%) mulheres, com idade média de 49,8 anos (faixa etária de 17 a 85 anos). Houve 47 (57,3%) casos de DCO periapical, 23 (28%) de DCO focal e 12 (14,6%) de DCO florida. A mandíbula foi mais afetada que a maxila. Na maioria dos casos, as lesões foram mistas ou hiperdensas. Todas as DCO apresentaram limites bem definidos e não houve casos de deslocamento dentário. Em conclusão, a DCO periapical foi o tipo mais comum e o osso mais afetado foi a mandíbula. A avaliação da imagem é crítica para o seu diagnóstico e os dentistas devem ter em mente todas as possíveis apresentações radiográficas da DCO, a fim de prevenir diagnósticos enganosos e, conseqüentemente, tratamentos inadequados.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Cementoma/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos
15.
Braz Dent J ; 29(1): 99-104, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29267533

RESUMO

Imaging exams have important role in diagnosis of cemento-osseous dysplasia (COD). Cone beam computed tomography (CBCT) stands out for allowing three-dimensional image evaluation. This study aimed to assess the prevalence of cases diagnosed as COD on CBCT scans, as well identify the main imaging features related to these lesions. An analysis was performed in a database containing 22,400 radiological reports, in which all cases showing some type of COD were initially selected. These CBCT exams were reevaluated to confirm the radiographic diagnosis and determine the prevalence and distribution of the types of COD with regard to gender, age and preferred location, while describing its most common imaging aspects. Data were presented using descriptive analyses. There were 82 cases diagnosed as COD in the CBCT images (prevalence of 0.4%). The distribution of patients was 11 (13.4%) male and 71 (86.6%) female, with a mean age of 49.8 years (age-range 17-85 years). There were 47 (57.3%) cases of periapical COD, 23 (28%) of focal COD and 12 (14.6%) of florid COD. The mandible was more affected than the maxilla. In most cases, the lesions were mixed or hyperdense. All COD had well-defined limits and there were no cases of tooth displacement. In conclusion, periapical COD was the most common type and the most affected bone was the mandible. Imaging evaluation is critical for diagnosis and dentists should bear in mind all possible radiographic presentations of COD in order to prevent misleading diagnoses and consequently, inadequate treatments.


Assuntos
Cementoma/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Clin Oral Investig ; 21(1): 301-307, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26984823

RESUMO

OBJECTIVES: The aims of this study were to evaluate microbial contamination in phosphor storage plates in dental radiology services and discuss the possible origin of this contamination. MATERIALS AND METHODS: The sample comprised 50 phosphor plates: 14 plates from service A, 30 from service B, and 6 in the control group, consisting of plates never used. Damp sterile swabs were rubbed on the phosphor plates, and then transferred to tests tubes containing sterile saline solution. Serial dilutions were made, and then inoculated in triplicate on Mueller Hinton agar plates and incubated at 37 °C/48 h, before counting the colony-forming units (CFU). The samples were also seeded in brain-heart infusion medium to confirm contamination by turbidity of the culture medium. All solutions, turbid and clean, were seeded in selective and non-selective media. RESULTS: At service A and B, 50 and 73.3 % of the phosphor plates were contaminated, respectively. This contamination was mainly due to bacteria of the genus Staphylococcus. CFU counts ranged from 26.4 to 80.0 CFU/plate. CONCLUSIONS: Most of the phosphor plates evaluated shown to be contaminated, mainly by Staphylococcus ssp. Quantitatively, this contamination occurred at low levels, possibly arising from handling of the plates. The use of a second plastic barrier may have diminished contamination by microorganisms from the oral cavity. CLINICAL RELEVANCE: There is a risk of cross-contamination by phosphor storage plates used in dental radiology services.


Assuntos
Contaminação de Equipamentos , Controle de Infecções Dentárias , Radiografia Dentária Digital/instrumentação , Staphylococcus/isolamento & purificação , Contagem de Colônia Microbiana , Humanos
17.
J Endod ; 42(10): 1509-15, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27522456

RESUMO

INTRODUCTION: The maxillary sinus can be affected by dental infections because of its close relationship with upper teeth. This study aimed to assess the most common types of maxillary sinus alterations and to associate them with odontogenic conditions using cone-beam computed tomographic (CBCT) images. METHODS: CBCT scans of 400 patients showing sinus disease in 1 or both maxillary sinuses were evaluated. Sinus alteration was considered as follows: generalized or localized mucosal thickening (MT), maxillary sinusitis (MS), and retention cysts (RCs). The odontogenic conditions evaluated were inadequate endodontic treatment, periapical lesions, and periodontal bone loss. Descriptive and multiple logistic regression analyses were performed. RESULTS: Sinus diseases were observed in 85.9% of the maxillary sinuses. The most prevalent condition was generalized MT (65.2%) followed by localized MT (24.8%), MS (6.4%), and RCs (3.6%). Generalized MT was more related to males (odds ratio = 1.45, P < .05) and periodontal bone loss (P < .05). Localized MT was associated with periapical lesions (odds ratio = 3.09, P < .05) and showed a close anatomic relationship between teeth and the sinus floor (odds ratio = 2.77, P < .05). There were no statistically significant associations between either MS or RCs and the odontogenic conditions studied. CONCLUSIONS: The most prevalent sinus diseases were the generalized and localized MT, and they were the only ones related to odontogenic conditions (periodontal bone loss and periapical lesions, respectively). We emphasize that CBCT imaging is an appropriate method for evaluating the maxillary sinus findings and their associated odontogenic conditions.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Seio Maxilar/diagnóstico por imagem , Sinusite Maxilar/diagnóstico por imagem , Odontogênese/fisiologia , Doenças dos Seios Paranasais/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Seio Maxilar/anatomia & histologia , Seio Maxilar/patologia , Sinusite Maxilar/etiologia , Sinusite Maxilar/patologia , Pessoa de Meia-Idade , Doenças dos Seios Paranasais/patologia , Doenças Periapicais/diagnóstico por imagem , Doenças Periapicais/patologia , Adulto Jovem
18.
Imaging Sci Dent ; 46(2): 69-75, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27358813

RESUMO

PURPOSE: Sufficient area in the interforaminal region is required for dental implant placement, and the anterior loop of the mandibular canal is located within the limits of this area. The aim of this study was to evaluate the prevalence and extent of the anterior loop in a Brazilian sample population using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. RESULTS: An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, 1.1±0.8 mm). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). CONCLUSION: In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles.

19.
Forensic Sci Int ; 262: 227-32, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27045380

RESUMO

The aim of this study was to verify the applicability and reproducibility of the FSS system [8] adapted for frontal and lateral cephalometric radiographs of the frontal sinus for human identification purposes. Eighty lateral and frontal digital cephalometric radiographs from a private Dental Radiology service's database were evaluated. Evaluations were performed in a dimmed lighting room, using a 4.200 lux lightbox with mask, ultrafan paper and pencil with a 0.5 diameter tip. The sheet of paper was superimposed on the radiograph to obtain the outlines of the frontal sinus and two examiners made the drawings independently at two different times, with a minimum period interval between evaluations. To obtain the linear physical measurements of the frontal sinus, a digital pachymeter was used. Later, all the discrete variables were codded for the statistical analysis. All variables were tested by means of the Cohen's Kappa test. The intraexaminer agreement ranged from good to perfect (p<0.001), while the interexaminer agreement ranged from regular to perfect (p<0.001). The use of frontal and lateral cephalometric radiographs was found to be reproducible and reliable for human identification by an adaptation of FSS system.


Assuntos
Cefalometria , Antropologia Forense/métodos , Seio Frontal/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
20.
Forensic Sci Int ; 262: 183-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27044030

RESUMO

The objective of this study was to evaluate the applicability of human identification parameters, established by Tatlisumak et al. (2007), by means of cone-beam computed tomography and extraoral radiographs of the frontal sinus region. From a total of 58 dry skulls, 26 were selected. Posteroanterior, profile cephalometric radiographs and cone-beam computed tomography images were acquired, adopting a specific method for reproducibility purposes. The images were evaluated by two examiners, previously calibrated, in a darkened environment and at two distinct sessions, with a minimum of 15 days between them. The characteristics of the frontal sinus were analyzed using the Cohen's kappa test, for categorical variables, and Lin's concordance correlation coefficient (CCC) for continuous variables. Acceptable values of inter method variability for the categorical variables were found, while same cannot be told for continuous variables. The parameters evaluated for the frontal sinus on extraoral radiographs and cone-beam computed tomographs were mostly concordant, with the exception of three. Categorical and discrete variables showed an intra- and interexaminer concordance ranging from good to perfect, and the quantitative continuous variables showed concordance ranging from moderate to excellent. The parameters examined are applicable and reproducible using multiplanar reconstructions of cone-beam computed tomography and extraoral radiographs of the frontal sinus.


Assuntos
Antropologia Forense/métodos , Seio Frontal/diagnóstico por imagem , Cefalometria , Tomografia Computadorizada de Feixe Cônico , Humanos , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...